.\" Copyright (c) 2004-2005 Pawel Jakub Dawidek .\" All rights reserved. .\" .\" Redistribution and use in source and binary forms, with or without .\" modification, are permitted provided that the following conditions .\" are met: .\" 1. Redistributions of source code must retain the above copyright .\" notice, this list of conditions and the following disclaimer. .\" 2. Redistributions in binary form must reproduce the above copyright .\" notice, this list of conditions and the following disclaimer in the .\" documentation and/or other materials provided with the distribution. .\" .\" THIS SOFTWARE IS PROVIDED BY THE AUTHORS AND CONTRIBUTORS ``AS IS'' AND .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE .\" ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHORS OR CONTRIBUTORS BE LIABLE .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF .\" SUCH DAMAGE. .\" .\" $FreeBSD: head/sbin/geom/class/raid3/graid3.8 267667 2014-06-20 09:40:43Z bapt $ .\" .Dd January 15, 2012 .Dt GRAID3 8 .Os .Sh NAME .Nm graid3 .Nd "control utility for RAID3 devices" .Sh SYNOPSIS .Nm .Cm label .Op Fl Fhnrvw .Op Fl s Ar blocksize .Ar name .Ar prov prov prov ... .Nm .Cm clear .Op Fl v .Ar prov ... .Nm .Cm configure .Op Fl adfFhnrRvwW .Ar name .Nm .Cm rebuild .Op Fl v .Ar name .Ar prov .Nm .Cm insert .Op Fl hv .Op Fl n Ar number .Ar name .Ar prov .Nm .Cm remove .Op Fl v .Fl n Ar number .Ar name .Nm .Cm stop .Op Fl fv .Ar name ... .Nm .Cm list .Nm .Cm status .Nm .Cm load .Nm .Cm unload .Sh DESCRIPTION The .Nm utility is used for RAID3 array configuration. After a device is created, all components are detected and configured automatically. All operations such as failure detection, stale component detection, rebuild of stale components, etc.\& are also done automatically. The .Nm utility uses on-disk metadata (the provider's last sector) to store all needed information. .Pp The first argument to .Nm indicates an action to be performed: .Bl -tag -width ".Cm configure" .It Cm label Create a RAID3 device. The last given component will contain parity data, whilst the others will all contain regular data. The number of components must be equal to 3, 5, 9, 17, etc.\& (2^n + 1). .Pp Additional options include: .Bl -tag -width ".Fl h" .It Fl F Do not synchronize after a power failure or system crash. Assumes device is in consistent state. .It Fl h Hardcode providers' names in metadata. .It Fl n Turn off autosynchronization of stale components. .It Fl r Use parity component for reading in round-robin fashion. Without this option the parity component is not used at all for reading operations when the device is in a complete state. With this option specified random I/O read operations are even 40% faster, but sequential reads are slower. One cannot use this option if the .Fl w option is also specified. .It Fl s Manually specify array block size. Block size will be set equal to least common multiple of all component's sector sizes and specified value. Note that array sector size calculated as multiple of block size and number of regular data components. Big values may decrease performance and compatibility, as all I/O requests have to be multiple of sector size. .It Fl w Use verify reading feature. When reading from a device in a complete state, also read data from the parity component and verify the data by comparing XORed regular data with parity data. If verification fails, an .Er EIO error is returned and the value of the .Va kern.geom.raid3.stat.parity_mismatch sysctl is increased. One cannot use this option if the .Fl r option is also specified. .El .It Cm clear Clear metadata on the given providers. .It Cm configure Configure the given device. .Pp Additional options include: .Bl -tag -width ".Fl a" .It Fl a Turn on autosynchronization of stale components. .It Fl d Do not hardcode providers' names in metadata. .It Fl f Synchronize device after a power failure or system crash. .It Fl F Do not synchronize after a power failure or system crash. Assumes device is in consistent state. .It Fl h Hardcode providers' names in metadata. .It Fl n Turn off autosynchronization of stale components. .It Fl r Turn on round-robin reading. .It Fl R Turn off round-robin reading. .It Fl w Turn on verify reading. .It Fl W Turn off verify reading. .El .It Cm rebuild Rebuild the given component forcibly. If autosynchronization was not turned off for the given device, this command should be unnecessary. .It Cm insert Add the given component to the existing array, if one of the components was removed previously with the .Cm remove command or if one component is missing and will not be connected again. If no number is given, new component will be added instead of first missed component. .Pp Additional options include: .Bl -tag -width ".Fl h" .It Fl h Hardcode providers' names in metadata. .El .It Cm remove Remove the given component from the given array and clear metadata on it. .It Cm stop Stop the given arrays. .Pp Additional options include: .Bl -tag -width ".Fl f" .It Fl f Stop the given array even if it is opened. .El .It Cm list See .Xr geom 8 . .It Cm status See .Xr geom 8 . .It Cm load See .Xr geom 8 . .It Cm unload See .Xr geom 8 . .El .Pp Additional options include: .Bl -tag -width ".Fl v" .It Fl v Be more verbose. .El .Sh EXIT STATUS Exit status is 0 on success, and 1 if the command fails. .Sh EXAMPLES Use 3 disks to setup a RAID3 array (with the round-robin reading feature). Create a file system, mount it, then unmount it and stop device: .Bd -literal -offset indent graid3 label -v -r data da0 da1 da2 newfs /dev/raid3/data mount /dev/raid3/data /mnt \&... umount /mnt graid3 stop data graid3 unload .Ed .Pp Create a RAID3 array, but do not use the automatic synchronization feature. Rebuild parity component: .Bd -literal -offset indent graid3 label -n data da0 da1 da2 graid3 rebuild data da2 .Ed .Pp Replace one data disk with a brand new one: .Bd -literal -offset indent graid3 remove -n 0 data graid3 insert -n 0 data da5 .Ed .Sh SEE ALSO .Xr geom 4 , .Xr geom 8 , .Xr gvinum 8 , .Xr mount 8 , .Xr newfs 8 , .Xr umount 8 .Sh HISTORY The .Nm utility appeared in .Fx 5.3 . .Sh AUTHORS .An Pawel Jakub Dawidek Aq Mt pjd@FreeBSD.org .Sh BUGS There should be a section with an implementation description. .Pp Documentation for sysctls .Va kern.geom.raid3.* is missing.